GLORIA

GEOMAR Library Ocean Research Information Access

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
Document type
Years
  • 1
    ISSN: 1600-0501
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Medicine
    Notes: Abstract: The aim of the present investigation was to assess the effect of four implant surface preparation methods used in the surgical treatment of experimental peri-implantitis with autogenous bone graft and expanded polytetrafluoroethylene (ePTFE) membrane. The methods were air-powder abrasive unit+citric acid, air-powder abrasive unit, gauze soaked in saline+citric acid, and gauze soaked alternately in chlorhexidine and saline. A total of 64 implants with a titanium plasma-sprayed (TPS) surface was placed in eight cynomolgus monkeys (Macaca fascicularis). After a 3-month period with plaque control, experimental peri-implantitis was induced. A bone loss of 4–6 mm was established after 9–17 months and plaque control was re-implemented. The peri-implantitis defects were surgically exposed, granulation tissue was removed, and each implant surface was prepared by one of the above-mentioned procedures. The defects were then filled with autogenous bone graft particles and covered by an ePTFE membrane. The animals were sacrificed after 6 months. Evaluation by clinical parameters, radiography including quantitative digital subtraction radiography, histology, and stereology did not reveal significant differences between the methods. Almost total bone regeneration and considerable re-osseointegration were obtained irrespective of the method applied. A mean bone-to-implant contact of 39–46% was observed within the defects. Therefore, the present study of implants with a TPS surface in cynomolgus monkeys indicates that the simplest method involving gauze soaked alternately in chlorhexidine and saline should be the preferred implant surface preparation method in the surgical treatment of peri-implantitis involving autogenous bone graft and ePTFE membrane.
    Type of Medium: Electronic Resource
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
  • 2
    ISSN: 1600-0501
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Medicine
    Notes: Abstract: The purpose of the present study was to evaluate the effect of autogenous bone graft particles and expanded polytetrafluoroethylene (ePTFE) membrane in the treatment of peri-implantitis with stereologic and histologic methods. Clinical and radiographic findings are reported elsewhere. Experimental peri-implantitis with a bone loss of 4–6 mm was established during 14–22 months around 64 implants with a titanium plasma-sprayed (TPS) surface in eight cynomolgus monkeys (Macaca fascicularis). The defects were treated with autogenous bone+membrane (B+M), autogenous bone (B), membrane (M), or a conventional flap procedure (control) (C). The animals were killed 6 months after surgery. Healthy peri-implant tissue was established irrespective of the applied treatment procedure. However, the amount of bone (autogenous bone graft particles and regenerated bone) and re-osseointegration were significantly higher in defects treated with B+M as compared with the three other treatment modalities. A mean bone-to-implant contact of 45% was estimated within defects treated with B+M. The corresponding values for the B, M, and C groups were 22, 21, and 14%. The present study therefore demonstrates that autogenous bone graft particles covered by an ePTFE membrane is a useful surgical treatment procedure of experimental peri-implantitis around implants with a TPS surface in cynomolgus monkeys. Obviously, there is a background for long-term evaluation in humans.
    Type of Medium: Electronic Resource
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    Oxford, UK : Munksgaard International Publishers
    Clinical oral implants research 13 (2002), S. 0 
    ISSN: 1600-0501
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Medicine
    Notes: Abstract: The purpose of this study was to obtain a better understanding of probing measurements around osseointegrated oral implants. A comparison was made of probe tip position around Astra Tech implants and teeth of eight cynomolgus monkeys (Macaca fascicularis) in conditions of i) healthy peri-implant mucosa/gingiva, ii) mild mucositis/gingivitis, iii) severe mucositis/gingivitis or iv) peri-implantitis/periodontitis. Histological sections of 128 probes that were attached to implants or teeth with surrounding tissues were prepared by the cutting-grinding technique. No systematic differences were identified in the clinical and histological estimates of the distance between the mucosal/gingival margin and the probe tip. The differences were mainly smaller than 0.5 mm, and in no case were they larger than 0.7 mm. For implants and teeth with healthy peri-implant mucosa/gingiva, the distance between the probe tip and the alveolar bone was similar and ranged from 0.5 to 1.5 mm (P = 0.97). However, the probe tip was closer to bone around implants than around teeth in conditions of mild mucositis/gingivitis (P = 0.034), severe mucositis/gingivitis (P ≤ 0.0001) and peri-implantitis/periodontitis (P ≤ 0.0001). Around implants with severe mucositis and peri-implantitis, the distance was generally smaller than 0.5 mm, whereas teeth with severe gingivitis and periodontitis showed distances that mainly ranged from 0.5 to 1.5 mm. In conclusion, the probing measurements around osseointegrated oral implants and teeth were different. Even mild marginal inflammation was associated with deeper probe penetration around implants in comparison to teeth.
    Type of Medium: Electronic Resource
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
  • 4
    ISSN: 1600-0501
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Medicine
    Notes: Abstract: The purpose of the present study was to evaluate the effect of anorganic porous bovine-derived bone mineral (Bio-Oss®) and expanded polytetrafluoroethylene (ePTFE) membrane in the treatment of peri-implantitis. A total of 64 implants with a titanium plasma-sprayed (TPS) surface was inserted in eight cynomolgus monkeys (Macaca fascicularis). After a 3-month healing period with plaque control, experimental peri-implantitis characterized by a bone loss of 4–6 mm was induced during a period of 9–18 months. Surgical treatment involving Bio-Oss+membrane, Bio-Oss, membrane, or a conventional flap procedure (control) only was carried out. The animals were sacrificed six months after treatment. Evaluation by clinical parameters, radiography including quantitative digital subtraction radiography, histology, and stereology demonstrated healthy peri-implant tissue irrespective of the applied surgical procedure. However, the amount of re-osseointegration and the total amount of bone (Bio-Oss and regenerated bone) were significantly higher in defects treated with membrane-covered Bio-Oss as compared with the other three treatment procedures. A mean bone-to-implant contact of 36% was obtained within defects treated with membrane-covered Bio-Oss. The corresponding values for the three other treatment procedures were 13–23%. The Bio-Oss particles were in general highly integrated within the regenerated bone, but the particles in the occlusal part of the defects were entirely surrounded by connective tissue irrespective of membrane coverage. The present study demonstrates that surgical treatment involving Bio-Oss covered by an ePTFE membrane is a useful treatment modality of experimental peri-implantitis around implants with a TPS surface in cynomolgus monkeys. However, the treatment outcome is not as encouraging as seen with membrane-covered autogenous bone graft particles documented in a study with same experimental design.
    Type of Medium: Electronic Resource
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...