GLORIA

GEOMAR Library Ocean Research Information Access

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
Document type
Years
  • 1
    ISSN: 1540-8159
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Medicine
    Notes: Pacing threshold is affected by many factors. A pacing system able to confirm capture at each beat and automatically adjust its output close to the actual pacing threshold is highly desirable. This study evaluates the safety and efficacy of the Autocapture function of the Pacesetter Microny SR+. One hundred thirteen patients were recruited from 16 centers in 7 European countries and followed up for 1 year. All pacemakers were implanted with Pacesetter's low polarization, bipolar leads. The key feature of Autocapture is the immediate delivery of a 4.5 V safety backup pulse 62.5 ms after any ineffective ongoing low output pulse. Holter recordings confirmed total reliability of this feature without any exit block. The measured evoked response (ER) signal was stable over time. Acute and chronic pacing thresholds measured by VARIO and Autocapture tests correlated (r 〉 0.79) over the period of the study. The incidence of backup pulses was 1.1% during pacing. With Autocapture programmed ON, the overall total current consumption was 4.1 μA for VVI and 5.0 μA for VVIR pacing. Tbis study proved that the Autocapture safely and reliably regulates the pacemaker's output according to the prevailing threshold thus providing maximum patient safety and prolonging service life.
    Type of Medium: Electronic Resource
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Oxford, UK : Blackwell Publishing Ltd
    Pacing and clinical electrophysiology 20 (1997), S. 0 
    ISSN: 1540-8159
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Medicine
    Notes: The main disadvantages of bipolar pacing leads have traditionally been related to their relative thickness and stiffness compared to unipolar leads. In a new “drawn filled tube” plus “coated wire” technology, each conductor strand is composed of MP35N tubing filled with silver core and coated with a thin ETFE polymer insulation material. This and parallel winding of single anode and cathode conductors into a single bifilar coil resulted in a bipolar lead (ThinLine, Intermedics) with a body diameter and flexibility similar to unipolar leads. The lead is tined. polyurethane. with the cathode and the anode made of iridium-oxide-coated titanium (IROX). The slotted 8-mm2 cathode tip is coated with polyethylene glycol. a blood soluble material. We present the clinical evaluation results from four pacemaker clinics, where 47 leads (23 atrial-J model 432–04 and 24 ventricular model 430–10) were implanted in 25 patients and followed for up to 2 years. The lead handling characteristics were found to be very satisfactory. Electrical parameters of the leads were measured at implant and noninvasively on postoperative days 1, 2, 21, 42. and months 3, 6, 12, and 24. Mean chronic pulse width thresholds at 2.5 V were 0.14 ± 0.05 ms in the atrium and 0.10 ± 0.02 ms in the ventricle, pacing impedances 443 ± 104 Ω and 520 ± 241 Ω. while median electrogram amplitudes were ≥ 3.5 mV and ≥ 7 m V, respectively. Pacing impedances and thresholds were found to be slightly but statistically significantly higher in unipolar than in bipolar configuration—the findings are explainable bv the lead construction. One of 47 leads failed 3 weeks after implant; the conductors were short circuited due to an error during the manufacturing process. We conclude that the new lead thus far has demonstrated appropriate mechanical and electrical characteristics.
    Type of Medium: Electronic Resource
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
Close ⊗