GLORIA

GEOMAR Library Ocean Research Information Access

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Publication Date: 2024-01-15
    Description: The formation of low stratus cloud over idealized hills is investigated using numerical model simulations. The main driver for the cloud formation is radiative cooling due to outgoing longwave radiation. Despite a purely horizontal flow, the advection terms in the prognostic equations for heat and moisture produce vertical mixing across the upper cloud edge, leading to a loss of cloud water content. This behavior is depicted via a budget analysis. More precisely, this spurious mixing is caused by the diffusive error of the advection scheme in regions where the sloping surfaces of the terrain‐following vertical coordinate intersect the cloud top. This study shows that the intensity of the (spurious) numerical diffusion depends strongly on the horizontal resolution, the order of the advection schemes, and the choice of scalar advection scheme. A large‐eddy simulation with 4‐m horizontal resolution serves as a reference. For horizontal resolutions of a few hundred meters and simulations carried out with a model setup as used in numerical weather prediction, a strong reduction of the simulated liquid‐water path is observed. In order to keep the (spurious) numerical diffusion at coarser resolutions small, at least a fifth‐order advection scheme should be used. In the present case, a weighted essentially nonoscillatory scalar advection scheme turns out to increase the numerical diffusion along a sharp cloud edge compared with an upwind scheme. Furthermore, the choice of vertical coordinate has a strong impact on the simulated liquid‐water path over orography. With a modified definition of the sigma coordinate, it is possible to produce cloud water where the classical sigma coordinate does not allow any cloud formation.
    Description: Diffusive errors of the advection scheme reduce the cloud water content of low stratus over idealized hills. This is due to the terrain‐following vertical coordinate and depends strongly on the horizontal resolution. Orographic features should be represented by at least 𝒪(10) grid points and a fifth‐order advection scheme (or higher) should be used. A weighted essentially nonoscillatory scalar advection scheme increases numerical diffusion along a sharp cloud edge compared with an upwind scheme. Modifying the definition of the sigma coordinate leads to a strong gain in the simulated liquid‐water path.
    Description: Deutsche Forschungsgemeinschaft http://dx.doi.org/10.13039/501100001659
    Description: Hans Ertel Centre for Weather Research
    Keywords: ddc:551.5 ; advection ; fog ; low stratus ; resolution ; rolling terrain ; vertical coordinate
    Language: English
    Type: doc-type:article
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
  • 2
    Publication Date: 2024-02-07
    Description: Numerical weather prediction models operate on grid spacings of a few kilometers, where deep convection begins to become resolvable. Around this scale, the emergence of coherent structures in the planetary boundary layer, often hypothesized to be caused by cold pools, forces the transition from shallow to deep convection. Yet, the kilometer-scale range is typically not resolved by standard surface operational measurement networks. The measurement campaign FESSTVaL aimed at addressing this gap by observing atmospheric variability at the hectometer to kilometer scale, with a particular emphasis on cold pools, wind gusts and coherent patterns in the planetary boundary layer during summer. A unique feature was the distribution of 150 self-developed and low-cost instruments. More specifically, FESSTVaL included dense networks of 80 autonomous cold pool loggers, 19 weather stations and 83 soil sensor systems, all installed in a rural region of 15-km radius in eastern Germany, as well as self-developed weather stations handed out to citizens. Boundary layer and upper air observations were provided by 8 Doppler lidars and 4 microwave radiometers distributed at 3 supersites; water vapor and temperature were also measured by advanced lidar systems and an infrared spectrometer; and rain was observed by a X-band radar. An uncrewed aircraft, multicopters and a small radiometer network carried out additional measurements during a four-week period. In this paper, we present FESSTVaL’s measurement strategy and show first observational results including unprecedented highly-resolved spatio-temporal cold-pool structures, both in the horizontal as well as in the vertical dimension, associated with overpassing convective systems.
    Type: Article , PeerReviewed
    Format: text
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...