  • 1
    ISSN: 1540-8167
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Medicine
    Notes: De. brillation Threshold in Chronic and Reinduced AF. Introduction: Induced versus spontaneous atrial fibrillation (AF) is of interest for assessing atrial defibrillation threshold reproducibility. Methods and Results: Twenty-one patients with chronic AF underwent internal cardioversion with assessment of atrial defibrillation threshold at baseline and at reinduced AF. High right atrial (HRA) and coronary sinus (CS) bipolar recordings were analyzed to measure the mean local atrial period, its coefficient of variation, the 5th (P5) and 95th (P95) percentiles of atrial intervals, and the percentage of points lying at the baseline (number of occurrences), and to quantify AF organization. Atrial defibrillation threshold was comparable in baseline and reinduced AF in terms of leading-edge voltage and delivered energy. Baseline and reinduced AF were comparable with regard to overall signal parameters (both in HRA and CS) and the presence of an organized arrhythmia pattern. As for individual variables, P5 increased while P95 and coefficient of variation decreased in reinduced AF compared with spontaneous AF (statistical significance was achieved for all these parameters in HRA, but only for coefficient of variation and P95 in CS). Conclusion: Sustained AF reinduced after cardioversion of chronic AF is comparable with baseline AF in terms of atrial defibrillation threshold, atrial cycle length, and pattern of organization. Therefore, a clinical model based on reinduction of sustained AF after cardioversion is suitable for studying the effects of a series of interventions on atrial defibrillation threshold. However, because this model does not yield a form of AF with comparable indices of local refractoriness (e.g., P5), it is not recommended when analyzing local electrophysiologic properties.
    Type of Medium: Electronic Resource
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    350 Main Street , Malden , MA 02148-5018 , USA , and 9600 Garsington Road , Oxford OX4 2DQ , UK . : Blackwell Science Inc
    Journal of cardiovascular electrophysiology 16 (2005), S. 0 
    ISSN: 1540-8167
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Medicine
    Notes: Background: The pattern of FF intervals during atrial fibrillation (AF) has been analyzed in induced and spontaneous AF episodes, after the induction of ventricular fibrillation (VF) and after atrial shock, in order to suggest practical considerations for AF management in patients implanted with antitachycardia devices. Methods: In 13 patients implanted with a dual-chamber defibrillator, FF intervals were analyzed during two separate induced AF episodes, before and after VF induction over AF, as well as during spontaneous AF episodes and after unsuccessful atrial shocks. The following parameters were considered: mean atrial cycle length (CL), atrial CL stability, and standard deviation of the atrial cycle. Results: The AF pattern had comparable characteristics considering two separate inductions of AF, as well as spontaneous AF episodes. Ventricular tachyarrhythmia induction resulted in a shortening of atrial CL (P 〈 0.02) and in a less organized AF pattern (P 〈 0.005). Changes in the FF interval after ineffective shock therapy showed a shortening of AF cycles after shocks with energies far below the defibrillation threshold. Conclusions: (a) The AF pattern is reproducible in separate inductions of sustained AF and in spontaneous episodes, (b) dynamic changes involving a shortening of the AF cycle and an evolution to a less homogeneous pattern occur after VF induction, revealing a complex interplay between AF and VF, and (c) FF interval analysis after ineffective shock delivery may allow the relationship between delivered shock energy and effective defibrillation energy to be estimated, thereby providing practical suggestions for step-up protocols in atrial cardioversion.
    Type of Medium: Electronic Resource
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
  • 3
    ISSN: 1540-8167
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Medicine
    Notes: Background: Recent options to treat atrial tachyarrhythmias (ATA) include implantable devices delivering antitachycardia pacing therapies (ATP). No prospective study selected patients with higher chances of episode termination by ATP or indicated the most effective ATP use. Our aim was to study ATP efficacy in patients with brady-tachy form of sinus node disease (SND), identifying clinical factors, ATA characteristics, and device features predicting ATP efficacy. Methods and Results: Three hundred and sixteen patients (105 M, aged 71.1 ± 8.8 years) received a DDDRP pacemaker and were prospectively followed. Median follow-up was 18 months: 37,125 ATA episodes occurred in 217 patients; ATP treated 5,536 of them. Overall, ATP efficacy was 50.0%. A multivariate analysis identified longer arrhythmia cycle lengths (OR = 1.25; CI = 1.07-1.47) and shorter delays to ATP delivery (OR = 0.15; CI = 0.10-0.22) as independent predictors of ATP efficacy for episodes preceded by ≥5 minutes of sinus rhythm. Additionally, ATP efficacy for all treated episodes was predicted by lower New York Heart Association (NYHA) class (OR = 0.64; CI = 0.42-0.98), episode classification as nonimmediate recurrence of ATA (non-IRAT) (OR = 0.07; CI = 0.02-0.33), absence of overlap in the device detection windows (OR = 0.54; CI = 0.32-0.91), and flecainide treatment (OR = 2.22; CI = 1.04-4.71). Conclusions: In patients paced for SND, multivariate analysis shows that ATP efficacy is associated to longer arrhythmia cycle lengths, shorter ATP delivery delays, NYHA class I, episode classification as non-IRAT, absence of overlap in the atrial arrhythmia device detection windows, and flecainide treatment.
    Type of Medium: Electronic Resource
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
  • 4
    Electronic Resource
    Electronic Resource
    Oxford, UK : Blackwell Science Inc
    Journal of cardiovascular electrophysiology 13 (2002), S. 0 
    ISSN: 1540-8167
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Medicine
    Type of Medium: Electronic Resource
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
  • 5
    ISSN: 1546-1718
    Source: Nature Archives 1869 - 2009
    Topics: Biology , Medicine
    Notes: [Auszug] Many pathological processes, including those causing allergies and autoimmune diseases, are associated with the presence of specialized subsets of T helper cells at the site of inflammation. Understanding the genetic program that controls the functional properties of T helper type 1 (Th1) versus T ...
    Type of Medium: Electronic Resource
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
  • 6
    ISSN: 1540-8159
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Medicine
    Notes: BORIANI, G., et al.: Combined Use of Morphology Discrimination, Sudden Onset, and Stability as Discriminating Algorithms in Single Chamber Cardioverter Defibrillators. Morphology Discrimination (MD) is a rhythm discriminator based on QRS morphology analysis that can be combined with other discriminators like Stability, with or without Sinus Interval History (SIH) and Sudden Onset. Thirty-five patients implanted with a St. Jude Medical single chamber ICD were evaluated during exercise testing, during induced AF, and during follow-up for 14 ± 5 months. At exercise testing (60 episodes detected) MD had a specificity (SP) of 96.7% and Sudden Onset a SP of 91.7%; during induced AF (25 episodes) both MD and Stability had a SP of 96.0%. The diagnostic performance on spontaneous arrhythmias was as follows: for ventricular tachycardia (126 episodes) a sensitivity (SE) of 94.4% for MD, 92.1% for Sudden Onset, 89.7% for Stability without SIH and 79.4% for Stability + SIH; for sinus tachycardia (44 episodes) a SP of 86.4% for MD, 97.7% for Sudden Onset, 2.3% for Stability and of 95.5% for Stability + SIH. For AF (165 cases) a SP of 67.9% for MD, 69.1% for Stability and 90.3% for Stability + SIH, 44.8% for Sudden Onset. Use of MD alone provided a SE of 94.4% and a SP of 71.4% for spontaneous arrhythmias and combined use of the discriminators in a “2 of 3” diagnostic logic implied a SP of 90.9% with maintenance of 96.0% of SE. In single chamber ICDs a wide range of SE/SP ratios may be obtained by use of multiple discriminators, but use of the algorithm in a 2 of 3 diagnostic logic may achieve a SP of 90.9% and a SE of 96.0%.
    Type of Medium: Electronic Resource
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
  • 7
    Electronic Resource
    Electronic Resource
    350 Main Street , Malden , MA 02148-5018 , USA and 9600 Garsington Road , Oxford OX4 2DQ , UK . : Blackwell Science Inc
    Pacing and clinical electrophysiology 28 (2005), S. 0 
    ISSN: 1540-8159
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Medicine
    Notes: AutoCapture™ based on the evoked response can be confounded by electrode polarization. In this study, polarization was measured in human subjects who had chronic atrial leads. The aim of the study was to determine whether electrode polarization can be measured using a time integral atrial evoked-response integral (AERI) of the negative portion of the atrial paced ER evoked-response signal and to determine whether high-polarization atrial leads unsuitable for AutoCapture™ can be identified a priori. Atrial intracardiac-electrogram (IEGM) signals from 39 patients with implanted pacemakers were recorded and analyzed. The signals were recorded during conventional atrial-threshold searches. A total of 221 atrial-capture thresholds were recorded, ranging from 0.25 to 2.75 V with a mean of 0.79 V. Each evoked response was evaluated using the AERI in a 36 ms window following the 0.4 ms atrial stimulus. The polarization was estimated as a linear function of stimulus voltage using the evoked-response signal integral of captured beats identified on the IEGM. The 221 threshold-search datasets were obtained using leads with eight different electrode materials. Polarization could be measured using AERI as a function of stimulus voltage. Furthermore, this polarization measure can be used to identify high-polarization leads, which are ill suited for the atrial AutoCapture™ algorithm.
    Type of Medium: Electronic Resource
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
  • 8
    Electronic Resource
    Electronic Resource
    350 Main Street , Malden , MA 02148-5018 , USA and 9600 Garsington Road , Oxford OX4 2DQ , UK . : Blackwell Science Inc
    Pacing and clinical electrophysiology 28 (2005), S. 0 
    ISSN: 1540-8159
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Medicine
    Notes: Background: This study was conducted to evaluate the clinical performance of the ventricular automatic capture feature as implemented in the Insignia I Ultra pacemaker system (Guidant) utilizing a variety of ventricular leads Currently, the optimal programming of the pacemaker output considers both pacemaker efficiency (prolonging battery longevity) and patient safety (adequate safety margin). The ability of a pacemaker to automatically adjust the ventricular output above the pacing threshold while maintaining the appropriate safety margin has been explored since the early 1970s and is only available today in conjunction with a specific low polarization lead system. Methods: One hundred and five patients were enrolled from 17 European centers utilizing 31 different types of ventricular leads were followed through their 3-month follow-up visit. There were no restrictions on the type of ventricular leads used. Results: The average mean difference between the commanded autothreshold test (0.652 + 0.335 V) and the manual threshold test (0.651 + 0.335 V) was 0.001 + 0.49 (P 〈 0.0001). The average mean difference between the ambulatory autothreshold test (0.696 + 0.322 V) and the commanded autothreshold test (0.682 + 0.315 V) was 0.002 + 0.74 (P 〈 0.0001). Holter recordings confirmed that there were no loss of capture incidences without a backup pulse being delivered. In addition, the mean number of backup pulses delivered in a 24-hour period was less than 0.1% of the total number of paced beats. Conclusions: This study provided that the automatic capture feature while using a variety of leads accurately determines the ventricular stimulation threshold and safely delivers a backup pulse when required.
    Type of Medium: Electronic Resource
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
  • 9
    Electronic Resource
    Electronic Resource
    350 Main Street , Malden , MA 02148-5018 , USA . : Blackwell Futura Publishing, Inc.
    Pacing and clinical electrophysiology 26 (2003), S. 0 
    ISSN: 1540-8159
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Medicine
    Notes: BORIANI, G., et al.: Atrial Evoked Response Integral for Automatic Capture Verification in Atrial Pacing. Beat-by-beat Autocapture is currently limited to operation in the ventricle with bipolar leads. The authors investigated the integral of the negative-going portion of the atrial evoked response integral (AERI) as a potential resource for verification of atrial capture. Intracardiac electrogram signals were collected from 59 patients (ages 67.8 ± 15.1 years) with bipolar, low polarization atrial leads. The signals were collected over a mean period of 6.1 months (minimum 4 days) after lead implantation. St. Jude Medical Affinity pulse generators were used to perform automatic capture threshold tests while the electrogram signals were recorded by a Model 3510 programming device. These signals were transferred to a personal computer in digital form for later analysis. The AERI was calculated at each programmable pacing voltage until capture was lost. The difference between the polarization integral at loss of capture and evoked response integral with successful capture was sufficient to justify enabling the atrial Autocapture feature in 53 of 59 patients in whom bipolar pacing and unipolar sensing was performed. The authors developed a calibration routine to identify automatically those patients in whom atrial Autocapture could be programmed On, based on the polarization integral at loss of capture, the estimated maximum polarization integral, and the AERI. Preliminary analysis indicated that the AERI is a practical resource for beat-by-beat atrial capture detection when used with low polarization leads. (PACE 2003; 26[Pt. II]:248–252)
    Type of Medium: Electronic Resource
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
  • 10
    Electronic Resource
    Electronic Resource
    350 Main Street , Malden , MA 02148-5018 , USA . : Blackwell Futura Publishing, Inc.
    Pacing and clinical electrophysiology 26 (2003), S. 0 
    ISSN: 1540-8159
    Source: Blackwell Publishing Journal Backfiles 1879-2005
    Topics: Medicine
    Notes: BIFFI, M., et al.: Abnormal Cardiac Innervation in Patients with Idiopathic Ventricular Fibrillation. Idiopathic ventricular fibrillation (VF) is diagnosed in up to nearly 10% of survivors of out-of-hospital cardiac arrest. The arrhythmogenic substrate is unknown. This study examined the role of cardiac innervation as a possible contributor to this arrhythmia. Eight patients with idiopathic VF were compared with eight normal subjects (controls) by [123] I metaiodobenzylguanidine SPECT (MIBG), measuring peak uptake, late uptake, and clearance of the nuclear tracer. The left ventricle was divided in 13 segments in the bull's-eye target plot. Peak and late MIBG uptake was increased in the anterolateral segments (2,3,7,8) compared to the inferoposterior and septal segments, in controls and in patients. No difference was observed between controls and patients in the inferoposterior and septal segments. In contrast, a significantly higher MIBG uptake was observed in patients compared to controls in the anterolateral segments ( 94 ± 4% vs 81 ± 11%, P 〈 0.03 for peak uptake; 94 ± 5% vs 79 ± 12%, P 〈 0.01 for late uptake). No difference was observed in MIBG clearance in any segment in either study group. Cardiac sympathetic innervation is highly heterogeneous, though predominant in anterolateral segments in normal subjects. Patients with idiopathic VF exhibit the same distribution, though have a significantly greater density of sympathetic terminals in the anterolateral segments than controls, which may promote ventricular arrhythmias. (PACE 2003; 26[Pt. II]:357–360)
    Type of Medium: Electronic Resource
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...