GLORIA

GEOMAR Library Ocean Research Information Access

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
Document type
Keywords
Publisher
Years
  • 11
    Publication Date: 2024-05-14
    Description: The dataset contains temperature, salinity, oxygen saturation, chlorophyll a and turbidity data from the Helgoland MarGate underwater observatory from the year 2023 in a temporal resolution of 1 hour. The cabled observatory is located in 10m water depth and comprises single or multiple sensors for a specific parameter (see https://www.awi.de/en/science/biosciences/shelf-sea-system-ecology/main-research-focus/cosyna/underwater-node-helgoland.html). For a detailed description of the data see associated metadatafile metadata_heluwobs_2023_hydrography.pdf.
    Keywords: ACROSS; Advanced Remote Sensing – Ground-Truth Demo and Test Facilities; Alfred-Wegener-Institute; BAH; Chlorophyll a; Chlorophyll a, confidence value; Coastal Observing System for Northern and Arctic Seas; COSYNA; DATE/TIME; Helgoland, North Sea; Helgoland-UWO; Hereon; in situ observations; MarGate; MarGate underwater experimental area; Modular Observation Solutions for Earth Systems; MOSES; OBSE; Observation; Observatory; observatory data; Oxygen saturation; Oxygen saturation, confidence value; Salinity; Salinity, confidence value; Scientific diving; See further details: Metadata for the Helgoland underwater observatory; Shelf Seas Systems Ecology @ AWI (former Biologische Anstalt Helgoland); Temperature, water; Temperature, water, confidence value; Turbidity, confidence value; Turbidity (Formazin Turbidity Unit)
    Type: Dataset
    Format: text/tab-separated-values, 60652 data points
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
  • 12
    Publication Date: 2024-05-14
    Description: The dataset contains temperature, salinity, oxygen saturation, chlorophyll a and turbidity data from the Helgoland MarGate underwater observatory from the year 2022 in a temporal resolution of 1 hour. The cabled observatory is located in 10m water depth and comprises single or multiple sensors for a specific parameter (see https://www.awi.de/en/science/biosciences/shelf-sea-system-ecology/main-research-focus/cosyna/underwater-node-helgoland.html). For a detailed description of the data see associated metadatafile metadata_heluwobs_2022_hydrography.pdf.
    Keywords: ACROSS; Advanced Remote Sensing – Ground-Truth Demo and Test Facilities; Alfred-Wegener-Institute; BAH; Chlorophyll a; Chlorophyll a, confidence value; Coastal Observing System for Northern and Arctic Seas; COSYNA; DATE/TIME; Helgoland, North Sea; Helgoland-UWO; Hereon; in situ observations; MarGate; MarGate underwater experimental area; Modular Observation Solutions for Earth Systems; MOSES; OBSE; Observation; Observatory; observatory data; Oxygen saturation; Oxygen saturation, confidence value; Salinity; Salinity, confidence value; Scientific diving; See further details: Metadata for the Helgoland underwater observatory; Shelf Seas Systems Ecology @ AWI (former Biologische Anstalt Helgoland); Temperature, water; Temperature, water, confidence value; Turbidity, confidence value; Turbidity (Formazin Turbidity Unit)
    Type: Dataset
    Format: text/tab-separated-values, 49614 data points
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
  • 13
    Publication Date: 2021-09-14
    Repository Name: EPIC Alfred Wegener Institut
    Type: Article , isiRev
    Format: application/pdf
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
  • 14
    Publication Date: 2021-09-14
    Repository Name: EPIC Alfred Wegener Institut
    Type: Article , isiRev
    Format: application/pdf
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
  • 15
    Publication Date: 2023-06-21
    Description: A thorough and reliable assessment of changes in sea surface water temperatures (SSWTs) is essential for understanding the effects of global warming on long-term trends in marine ecosystems and their communities. The first long-term temperature measurements were established almost a century ago, especially in coastal areas, and some of them are still in operation. However, while in earlier times these measurements were done by hand every day, current environmental long-term observation stations (ELTOS) are often fully automated and integrated in cabled underwater observatories (UWOs). With this new technology, year-round measurements became feasible even in remote or difficult to access areas, such as coastal areas of the Arctic Ocean in winter, where measurements were almost impossible just a decade ago. In this context, there is a question over what extent the sampling frequency and accuracy influence results in long-term monitoring approaches. In this paper, we address this with a combination of lab experiments on sensor accuracy and precision and a simulated sampling program with different sampling frequencies based on a continuous water temperature dataset from Svalbard, Arctic, from 2012 to 2017. Our laboratory experiments showed that temperature measurements with 12 different temperature sensor types at different price ranges all provided measurements accurate enough to resolve temperature changes over years on a level discussed in the literature when addressing climate change effects in coastal waters. However, the experiments also revealed that some sensors are more suitable for measuring absolute temperature changes over time, while others are more suitable for determining relative temperature changes. Our simulated sampling program in Svalbard coastal waters over 5 years revealed that the selection of a proper sampling frequency is most relevant for discriminating significant long-term temperature changes from random daily, seasonal, or interannual fluctuations. While hourly and daily sampling could deliver reliable, stable, and comparable results concerning temperature increases over time, weekly sampling was less able to reliably detect overall significant trends. With even lower sampling frequencies (monthly sampling), no significant temperature trend over time could be detected. Although the results were obtained for a specific site, they are transferable to other aquatic research questions and non-polar regions.
    Repository Name: EPIC Alfred Wegener Institut
    Type: Article , isiRev
    Format: application/pdf
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...