    ISSN: 1045-4861
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: Anodic polarization measurements of several orthopaedic implant alloys - AISI 316L stainless steel, Co—Cr—Mo alloy (ASTM F-75), nickel-titanium (NiTi) alloy, commercial pure titanium, and Ti—6Al—4V - were carried out in Ringer's solution containing 1% bovine serum albumin (BSA) and in simple Ringer's solution. Constituent metals in the medium were analyzed by inductively coupled plasma emission spectrophotometry after measurements. Pitting potentials and total anodic current of former two alloys were constant in the two mediums and not affected by the addition of bovine serum albumin. However, the amount of dissolved metals from pure nickel and AISI 316L stainless steel were increased by the addition of BSA; dissolved metals from Co—Cr—Mo alloy were decreased by it.
    Additional Material: 5 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
  • 2
    ISSN: 1045-4861
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: We have developed a new poly(vinyl alcohol) hydrogel (PVA-H) of increased physical strength through a new manufacturing process. Its mechanical properties have been found to be preferable as a substitute for articular cartilage. To evaluate its biocompatibility as an artificial articular cartilage, a series of in vivo tests within the intraarticular, as well as the intramuscular, environment were conducted. Tissue reactions of cartilage, bone, synovium, and muscle to PVA-H were studied histologically. In the experimental group, in which PVA-H was implanted, inflammatory reactions of all of these tissues were very slight. In the control group, in which ultra-high molecular weight polyethylene (UHMWPE) was implanted, although tissue reactions of bone and muscle were as slight as in the experimental group, those of cartilage and synovium were somewhat more conspicuous. By way of these findings, the better biocompatibility of PVA-H was documented.
    Additional Material: 11 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
  • 3
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Journal of Applied Polymer Science 55 (1995), S. 857-863 
    ISSN: 0021-8995
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Chemistry and Pharmacology , Mechanical Engineering, Materials Science, Production Engineering, Mining and Metallurgy, Traffic Engineering, Precision Mechanics , Physics
    Notes: Polypropylene multifilament yarn samples were irradiated by gamma rays in air. The effect of radiation dose on thermal, structural, and mechanical properties was studied. Melting endotherms and crystallization exotherms gave useful information regarding the structural changes. X-ray diffraction, infrared spectroscopy, density, and viscosity data of the irradiated samples were analyzed. Although viscosity and mechanical properties decreased with irradiation, the density marginally increased. Breaking elongation has been found be a sensitive parameter for assessing deterioration. © 1995 John Wiley & Sons, Inc.
    Additional Material: 5 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
  • 4
    ISSN: 0021-9304
    Keywords: Chemistry ; Polymer and Materials Science
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Medicine , Technology
    Notes: Partially stabilized zirconia ceramic is being recognized among ceramics for its high strength and toughness. With this ceramic, is possible to manufacture a 22-mm-size femoral head for low friction arthroplasty of the hip joint in association with an ultra-high-molecular-weight polyethylene socket. Wear-resistant properties of zirconia ceramic were screened on two principally different wear devices. Sterile calf bovine serum, physiological saline, and distilled water were chosen as the lubricant fluid media. Depending on the lubricant medium, the wear factor of polyethylene against zirconia ceramic counterfaces was 40 to 60% less than that against alumina ceramic counterfaces, and 5 to 10 times lower than with the SUS316L metal counterfaces. Polyethylene wear against metal was more susceptible in saline in which it had 2 to 3 times higher wear rate than with serum. On the other hand, different fluid media had little effect on polyethylene wear against ceramic counterfaces. In each set of tests, the wear factor obtained on an unidirectional wear device showed 10 to 15 times higher values, in comparison to the wear factor estimated on a reciprocating wear device.