GLORIA

GEOMAR Library Ocean Research Information Access

feed icon rss

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    Electronic Resource
    Electronic Resource
    New York, NY [u.a.] : Wiley-Blackwell
    Biotechnology and Bioengineering 22 (1980), S. 377-399 
    ISSN: 0006-3592
    Keywords: Chemistry ; Biochemistry and Biotechnology
    Source: Wiley InterScience Backfile Collection 1832-2000
    Topics: Biology , Process Engineering, Biotechnology, Nutrition Technology
    Notes: The hydrophobic interaction of β-galactosidase with Sepharose 4B substituted with 3,3′-diaminodipropylamine was studied in both batch and column experiments. The equilibrium and the binding rate constants were determined for different phosphate buffer concentrations. The equilibrium constants exhibit a hysteresis effect, i.e., desorption constants are less than adsorption constants, and the higher the ionic strength to start the desorption, the larger the effect. The rate data are not satisfactorily described by a simple reversible first-order model. The column chromatographic data are semiquantitatively described by a local equilibrium theory without axial dispersion or intraparticle diffusion.
    Additional Material: 11 Ill.
    Type of Medium: Electronic Resource
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
  • 2
    Electronic Resource
    Electronic Resource
    Springer
    Fresenius' Zeitschrift für analytische Chemie 270 (1974), S. 187-190 
    ISSN: 1618-2650
    Keywords: Best. von Seltenen Erden in Thorium ; Spektralanalyse ; Gleichstrombogen
    Source: Springer Online Journal Archives 1860-2000
    Topics: Chemistry and Pharmacology
    Description / Table of Contents: Summary An emission spectrographic determination of fifteen rare earth elements in thorium was developed, the spectrographic procedure was carried out using low current d.c. arc and using Sc as an internal standard. The rare earth impurities were concentrated with cation-exchange resin. Very high sensitivity was achieved with 1 g sample. The detection limits range from 0.01 μg for Yb to 0.5 μg for Pr and Nd.
    Notes: Zusammenfassung 15 Seltene Erdelemente konnten in Thorium bestimmt werden. Zur Anwendung kam ein Gleichstrombogen niederer Stromstärke. Als innerer Standard diente Scandium. Zur Anreicherung der Seltenen Erden wurde ein Kationenaustauscher verwendet. Mit 1 g-Proben konnten hohe Empfindlichkeiten erzielt werden. Die Nachweisgrenzen liegen im Bereich von 0,01 μg (Yb) bis 0,5 μg (Pr, Nd).
    Type of Medium: Electronic Resource
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...