GLORIA

GEOMAR Library Ocean Research Information Access

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • Ovid Technologies (Wolters Kluwer Health)  (5)
Material
Publisher
  • Ovid Technologies (Wolters Kluwer Health)  (5)
Language
Years
Subjects(RVK)
  • 1
    In: Retina, Ovid Technologies (Wolters Kluwer Health), Vol. 41, No. 10 ( 2021-10), p. 2088-2097
    Abstract: To evaluate the association between female reproductive factors and the incidence of exudative age-related macular degeneration (AMD). Methods: A total of 1,297,388 postmenopausal women over 50 years of age who participated in both national health screening and cancer screening in 2009 were identified using the Korea National Health Insurance System database. Data on female reproductive factors were collected using a self-administered questionnaire. Patients were followed up until 2018, and the incident cases of exudative AMD were identified. The hazard ratios and 95% confidence intervals for exudative AMD were estimated using the multivariable-adjusted Cox proportional hazard model. Results: During a mean follow-up of 7.27 years, 4,086 patients were newly diagnosed with exudative AMD. The hazard ratio (95% confidence intervals) for exudative AMD was 1.14 (1.01–1.31) for a reproductive period ≥40 years compared with a reproductive period 〈 30 years, 1.72 (1.48–2.00) for patients with ≥5 years of hormone replacement therapy, and 1.29 (1.09–1.52) for those with 2 to 5 years of hormone replacement therapy compared with those who never underwent hormone replacement therapy. Conclusion: Female reproductive factors were associated with the risk of exudative AMD. Greater lifetime exposure to endogenous and exogenous estrogen was associated with a higher incidence of exudative AMD.
    Type of Medium: Online Resource
    ISSN: 0275-004X
    Language: English
    Publisher: Ovid Technologies (Wolters Kluwer Health)
    Publication Date: 2021
    detail.hit.zdb_id: 2071014-8
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
  • 2
    Online Resource
    Online Resource
    Ovid Technologies (Wolters Kluwer Health) ; 2023
    In:  Medicine Vol. 102, No. 2 ( 2023-01-13), p. e32633-
    In: Medicine, Ovid Technologies (Wolters Kluwer Health), Vol. 102, No. 2 ( 2023-01-13), p. e32633-
    Abstract: To determine the effectiveness of conjunctivoplasty using a modified argon laser photocoagulation method on patients with conjunctivochalasis (CCh). This study included 25 cases of symptomatic inferior CCh. After staining the surface of a redundant conjunctiva using a dark-purple marker, low-energy argon laser photocoagulation (500 μm spot size for 0.5 seconds at power 300 mW) was applied under topical anesthesia for a mean of 80 times. The patients were aged 67.6 ± 7.1 years (mean ± standard deviation). During a mean follow-up period of 7.8 months (range of 6–12 months), the CCh grades of 21 eyes (84%) decreased after laser conjunctivoplasty. Calculated reduction rates of grades 1, 2, and 3 were 90%, 75%, and 67%, respectively. Patient subjective symptoms were improved in 80% of cases. No postoperative complications such as conjunctival scarring or persistent ocular irritation were observed. Our modified argon laser photocoagulation method employs staining the conjunctival surface to increase the thermal laser energy absorbed by the target. This novel technique is simple and effective for treating mild-to-moderate-grade CCh in outpatient clinics.
    Type of Medium: Online Resource
    ISSN: 1536-5964
    Language: English
    Publisher: Ovid Technologies (Wolters Kluwer Health)
    Publication Date: 2023
    detail.hit.zdb_id: 2049818-4
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
  • 3
    Online Resource
    Online Resource
    Ovid Technologies (Wolters Kluwer Health) ; 2018
    In:  Eye & Contact Lens: Science & Clinical Practice Vol. 44, No. 5 ( 2018-09), p. 292-298
    In: Eye & Contact Lens: Science & Clinical Practice, Ovid Technologies (Wolters Kluwer Health), Vol. 44, No. 5 ( 2018-09), p. 292-298
    Abstract: To investigate the topographic factors related to axial length (AL) growth rate in orthokeratology. Methods: Clinical data of myopic children with orthokeratology lenses from 2010 to 2016 were investigated. Corneal topography (Orbscan II) and IOLMaster-measured AL at baseline and every posttreatment visit were analyzed. Optical map topographies from baseline- and posttreatment-stabilized corneas were analyzed to calculate the refractive power difference between the apex and the periphery (apex-periphery refractive power difference [ARPD]), which estimates the change of peripheral refraction. A generalized estimating equation (GEE) was used to assess the associations between AL growth and topographic changes in both eyes. Results: The mean baseline spherical equivalent (SE) was −2.40±1.12 diopters (D) and the mean AL was 24.38±0.77 mm. Over a mean follow-up period of 41.9 months, the mean AL growth rate was 0.22±0.15 mm/year. In a univariable GEE analysis, age at initial lens wear, baseline AL, baseline SE, central corneal thickness (CCT), baseline apex power, and posttreatment ARPD on optical topography maps were all significantly correlated with AL growth rate ( P 〈 0.001, 0.009, 0.024, 0.011, 0.010, and 0.006, respectively). In a multivariable GEE, CCT and posttreatment ARPD were identified as significant factors ( P =0.014 and 0.016, respectively). Conclusions: The AL growth rate was significantly associated with CCT and posttreatment relative peripheral refractive power, in addition to age at initial lens wear. These associations might possibly demonstrate an effect of treatment-induced peripheral refraction changes on retardation of myopic progression, whereas younger age might significantly influence both AL growth rate and corneal deformation.
    Type of Medium: Online Resource
    ISSN: 1542-2321
    Language: English
    Publisher: Ovid Technologies (Wolters Kluwer Health)
    Publication Date: 2018
    detail.hit.zdb_id: 2084291-0
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
  • 4
    Online Resource
    Online Resource
    Ovid Technologies (Wolters Kluwer Health) ; 2020
    In:  Cornea Vol. 39, No. 4 ( 2020-04), p. 514-518
    In: Cornea, Ovid Technologies (Wolters Kluwer Health), Vol. 39, No. 4 ( 2020-04), p. 514-518
    Abstract: To evaluate the effectiveness of conjunctival cyst removal using a modified method of argon laser photoablation. Methods: Seventeen cases of symptomatic conjunctival cysts were included. After staining the surface of a conjunctival cyst with a dark purple marker, the cyst was incised using a 26-gauge needle. Low-energy argon laser photoablation was then applied around the incision site for a mean of 100 times. Results: During a mean follow-up period of 13.3 months (range 6–28 months), all conjunctival cysts were successfully corrected by applying either one or 2 laser sessions. Complete resolution occurred after a single laser session in 14 eyes (82.4%). There were 3 cases of recurrence with medium to large cysts, and repeating the same procedure produced surgical success in all of these cases; the conjunctival cyst recurred again after the second laser session in one of the 3 eyes, but this spontaneously regressed without further treatment. No postoperative complications such as conjunctival scarring or persistent ocular irritation were observed. Conclusions: Our modified method of argon laser photoablation uses staining of the conjunctival cyst surface to increase the amount of thermal laser energy absorbed by the target. This novel technique is simple and effective for treating conjunctival cysts in an outpatient clinic.
    Type of Medium: Online Resource
    ISSN: 0277-3740
    RVK:
    RVK:
    Language: English
    Publisher: Ovid Technologies (Wolters Kluwer Health)
    Publication Date: 2020
    detail.hit.zdb_id: 2045943-9
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
  • 5
    Online Resource
    Online Resource
    Ovid Technologies (Wolters Kluwer Health) ; 2019
    In:  Medicine Vol. 98, No. 33 ( 2019-08), p. e16731-
    In: Medicine, Ovid Technologies (Wolters Kluwer Health), Vol. 98, No. 33 ( 2019-08), p. e16731-
    Abstract: The aim of the study was to report the surgical outcome of mini-incisional correction method to treat involutional entropion. This is a retrospective interventional case series of 46 eyelids in 31 patients with involutional entropion and significant ocular irritation. In this technique, after turning the lower eyelid inside out, threads are introduced into it through the conjunctiva close to the inferior fornix. The lower lid retractor and tarsus are then connected using threads. These threads are applied at 3 locations of the lower eyelid and tightening them results in the eyelid being everted and the correction of entropion. Surgical success was defined as no contact between the eyelashes and the globe during forced closure of the eyelids. Surgical failure was defined as persistence of the eyelashes remaining in contact with the globe or cosmetic dissatisfaction. During the mean follow-up period of 22.1 months (range, 12–34 months), 43 of the eyelids (93.5%) were successfully corrected. Two patients (3 eyelids) experienced recurrence: 1 had involutional entropion combined with a cicatricial component, and the other had blepharospasm and apraxia of eyelid opening related to Parkinsonism. No postoperative complications such as overcorrection, suture-knot exposure, or ocular irritation were observed. Our mini-incisional entropion repair is based on reinforcement of the lower eyelid retractors using transconjunctival buried sutures. This technique is a quick, simple, and predictive for involutional entropion repair, and has a high success rate.
    Type of Medium: Online Resource
    ISSN: 0025-7974 , 1536-5964
    Language: English
    Publisher: Ovid Technologies (Wolters Kluwer Health)
    Publication Date: 2019
    detail.hit.zdb_id: 2049818-4
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...