GLORIA

GEOMAR Library Ocean Research Information Access

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
  • 1
    In: Journal of Clinical Microbiology, American Society for Microbiology, Vol. 42, No. 6 ( 2004-06), p. 2476-2479
    Abstract: We previously reported a high degree of variation in the sensitivities of serodiagnostic kits for the detection of Chlamydophila pneumoniae in sera from healthy donors. Since a low predictive value of a test can impair its diagnostic value, we have extended our studies to samples from patients with pneumonia. We focused on the most promising enzyme-linked immunosorbent assays (ELISAs) (SeroCP and SeroCP Quant; Savyon) identified in our previous study and included a new ELISA (sELISA; Medac). The agreement between all ELISAs for immunoglobulin G (IgG) and a reference microimmunofluorescence (MIF) test for IgG (SeroFIA; Savyon) was ≥90% for a collective of 80 patients. The positive predictive values were all ≥93%. The negative predictive values ranged from 68 to 83%. False-negative results were obtained only for samples that had low titers in the MIF test. The correlation of the IgG antibody titers determined by the MIF and SeroCP Quant tests was high ( r sp = 0.9). Since the semiquantitative SeroCP and quantitative SeroCP Quant ELISAs achieved the highest sensitivities, they were evaluated further by using a second batch of sera from 50 patients with predominantly medium and low antibody titers in the MIF test and a control collection of sera from 80 children with negative MIF results. Again, the tests showed a high concordance with the MIF results (96%), and the antibody titers in the SeroCP Quant and MIF tests correlated well ( r sp = 0.8). The specificities determined with the negative sera were ≥99% for the SeroCP Quant test and 86% for the SeroCP test. These results show that ELISAs that are fast and objective deliver seroprevalence results, sensitivities, and specificities that are very similar to those of the MIF test.
    Type of Medium: Online Resource
    ISSN: 0095-1137 , 1098-660X
    RVK:
    Language: English
    Publisher: American Society for Microbiology
    Publication Date: 2004
    detail.hit.zdb_id: 1498353-9
    SSG: 12
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
  • 2
    In: Anesthesiology, Ovid Technologies (Wolters Kluwer Health), Vol. 99, No. 1 ( 2003-07-01), p. 81-89
    Abstract: Differing factors may alter the effects of antibody to tumor necrosis factor (TNF) in infection and sepsis. The authors tested whether bacteria type or treatment route alters antibody to TNF in a rat model of bacterial pneumonia. Methods Rats (n = 231) received similarly lethal doses of either intratracheal Escherichia coli or Staphylococcus aureus followed by treatment with either intratracheal or intraperitoneal antibody to TNF or control serum. Animals received antibiotics (cefotiam daily dose, 100 mg/kg) starting 4 h after inoculation and were studied for up to 96 h. Results Compared with S. aureus, E. coli increased serum TNF and interleukin-6 concentrations, lung lavage TNF concentrations, neutrophil counts, and alveolar-to-arterial oxygen gradients and decreased circulating neutrophils and lymphocytes (P & gt; or = 0.05 for all). Compared with controls, with both bacteria, except for lung lavage TNF concentrations (which decreased with intratracheal but not with intraperitoneal antibody to TNF), treatment route did not alter the effects of antibody to TNF on any parameter (P = not significant for all). Antibody to TNF reduced mortality rates (relative risk of death +/- SEM) with both E. coli (-1.6 +/- 0.6; P = 0.006) and S. aureus (-0.5 +/- 0.04; P = 0.185), but these reductions were greater with E. coli than with S. aureus in a trend approaching statistical significance (P = 0.09). Compared with controls, similarly (P = not significant) with both bacteria, antibody to TNF decreased lung lavage and tissue bacteria concentrations (both P & lt; 0.05) and serum TNF concentration (P & lt; 0.09) and increased circulating neutrophils and lymphocytes (both P & lt; or = 0.01). Compared with S. aureus, with E. coli antibody to TNF decreased alveolar-to-arterial oxygen gradients (P = 0.04) and increased serum interleukin-6 concentrations (P = 0.003). Conclusion Antibody to TNF improved host defense and survival rates with both lethal E. coli and S. aureus pneumonia, but protection was greater with E. coli, where TNF concentrations were higher than with S. aureus. The efficacy of antiinflammatory agents in sepsis may be altered by bacteria type.
    Type of Medium: Online Resource
    ISSN: 0003-3022
    RVK:
    Language: English
    Publisher: Ovid Technologies (Wolters Kluwer Health)
    Publication Date: 2003
    detail.hit.zdb_id: 2016092-6
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
  • 3
    Online Resource
    Online Resource
    American Society for Microbiology ; 2002
    In:  Journal of Clinical Microbiology Vol. 40, No. 5 ( 2002-05), p. 1603-1609
    In: Journal of Clinical Microbiology, American Society for Microbiology, Vol. 40, No. 5 ( 2002-05), p. 1603-1609
    Abstract: The seroprevalence of anti- Chlamydia pneumoniae -specific immunoglobulin G (IgG) antibodies is high in the adult population. Experience is required to perform a microimmunofluorescence test (MIF), the current “gold standard” for serological diagnosis, and the assay still lacks standardization. Partially automated enzyme-linked immunosorbent assays (ELISAs) and enzyme immunoassays (EIAs), which are more standardized and for which the reading of results is less subjective, have been developed. The different commercially available serological tests differ in their sensitivities and specificities, depending primarily on the antigen used. Therefore, we evaluated 11 different tests (10 were species specific, 1 was genus specific) for IgG antibodies using serum samples of 80 apparently healthy volunteers. The interpretation of the results was based on the results of the gold standard, MIF: a sample was judged positive if it was positive by at least three of the four different MIFs. Based on this internal standard, we found that 71% of the samples were positive, while 8% were false positive by some tests. The correlations between the results of the different MIFs ranged from 83 to 99%, and the correlations between the results of the MIFs and the different ELISAs and EIAs ranged from 78 to 98%. Comparison of the IgG titers measured by MIF showed good agreement ( r = 0.76 to 0.91). This analysis revealed that some ELISAs and EIAs fail to detect low IgG titers. The specificities of the species-specific tests varied from 95 to 100%, and the sensitivities varied from 58 to 100%. These results indicate that serological assays for the detection of anti- C. pneumoniae -specific IgG vary greatly in their sensitivities and specificities. MIF must still be considered the best method for the detection of IgG in apparently healthy subjects, but the sensitivities and specificities of new ELISAs approximate those of MIFs.
    Type of Medium: Online Resource
    ISSN: 0095-1137 , 1098-660X
    RVK:
    Language: English
    Publisher: American Society for Microbiology
    Publication Date: 2002
    detail.hit.zdb_id: 1498353-9
    SSG: 12
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
  • 4
    Online Resource
    Online Resource
    Elsevier BV ; 2001
    In:  International Journal of Hygiene and Environmental Health Vol. 203, No. 4 ( 2001-1), p. 335-345
    In: International Journal of Hygiene and Environmental Health, Elsevier BV, Vol. 203, No. 4 ( 2001-1), p. 335-345
    Type of Medium: Online Resource
    ISSN: 1438-4639
    Language: English
    Publisher: Elsevier BV
    Publication Date: 2001
    detail.hit.zdb_id: 2039765-3
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
  • 5
    In: Cytokine, Elsevier BV, Vol. 13, No. 1 ( 2001-01), p. 51-54
    Type of Medium: Online Resource
    ISSN: 1043-4666
    Language: English
    Publisher: Elsevier BV
    Publication Date: 2001
    detail.hit.zdb_id: 1463198-2
    SSG: 12
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...