GLORIA

GEOMAR Library Ocean Research Information Access

Your email was sent successfully. Check your inbox.

An error occurred while sending the email. Please try again.

Proceed reservation?

Export
Filter
  • Ha, Yong-Chan  (8)
  • Medicine  (8)
  • 1
    Online Resource
    Online Resource
    Ovid Technologies (Wolters Kluwer Health) ; 2011
    In:  Journal of Bone and Joint Surgery Vol. 93, No. Supplement_1 ( 2011-3-16), p. 75-84
    In: Journal of Bone and Joint Surgery, Ovid Technologies (Wolters Kluwer Health), Vol. 93, No. Supplement_1 ( 2011-3-16), p. 75-84
    Abstract: Advanced-stage osteonecrosis and a large area of necrotic bone are known risk factors for failure of transtrochanteric rotational osteotomy of the hip in patients with osteonecrosis. The purpose of this study was to determine whether there are other risk factors for failure of this osteotomy. METHODS: One hundred and five patients (113 hips) underwent an anterior transtrochanteric rotational osteotomy for the treatment of femoral head osteonecrosis and were followed for a mean of 51.3 months postoperatively. Radiographic failure was defined as secondary collapse or osteoarthritic change. Multivariate analysis was performed to assess factors associated with secondary collapse and osteophyte formation. The Kaplan-Meier product-limit method was used to estimate survival. RESULTS: Secondary collapse occurred in twenty-seven hips (24%), and fourteen hips (12%) were converted to a total hip arthroplasty. At the time of the most recent follow-up, the hip scores according to the system of Merle d'Aubigné et al. ranged from 6 to 18 points (mean, 15.8 points). Multivariate analysis showed that the stage of the necrosis (III or greater) (hazard ratio = 3.28; 95% confidence interval = 1.49 to 7.24), age of the patient (forty years or older) (hazard ratio = 1.08; 95% confidence interval = 1.02 to 1.14), body mass index (≥24 kg/m2) (hazard ratio = 1.19; 95% confidence interval = 1.03 to 1.38), and extent of the necrosis (a combined necrotic angle of ≥230°) (hazard ratio = 1.08; 95% confidence interval = 1.04 to 1.11) were associated with secondary collapse. Seven of the eighty-six hips without collapse showed progression to osteoarthritis. The survival rate at 110 months was 63.4% (95% confidence interval = 51.1% to 75.7%) with total hip arthroplasty or radiographic failure as the end point and 56.0% (95% confidence interval = 44.6% to 67.4%) with total hip arthroplasty, radiographic failure, or loss to follow-up as the end point. CONCLUSIONS: Our study showed that age, body mass index, and the stage and extent of the osteonecrosis were determining factors for secondary collapse, unsatisfactory clinical results, and conversion to total hip arthroplasty. These factors should be considered when selecting patients for a transtrochanteric rotational osteotomy. LEVEL OF EVIDENCE: Prognostic Level II . See Instructions to Authors for a complete description of levels of evidence. ORIGINAL ABSTRACT CITATION: “Effects of Age and Body Mass Index on the Results of Transtrochanteric Rotational Osteotomy for Femoral Head Osteonecrosis” (2010;92:314-21).
    Type of Medium: Online Resource
    ISSN: 0021-9355 , 1535-1386
    RVK:
    Language: English
    Publisher: Ovid Technologies (Wolters Kluwer Health)
    Publication Date: 2011
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
  • 2
    Online Resource
    Online Resource
    Ovid Technologies (Wolters Kluwer Health) ; 2010
    In:  The Journal of Bone & Joint Surgery Vol. 92, No. 2 ( 2010-02), p. 314-321
    In: The Journal of Bone & Joint Surgery, Ovid Technologies (Wolters Kluwer Health), Vol. 92, No. 2 ( 2010-02), p. 314-321
    Type of Medium: Online Resource
    ISSN: 0021-9355
    RVK:
    Language: English
    Publisher: Ovid Technologies (Wolters Kluwer Health)
    Publication Date: 2010
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
  • 3
    Online Resource
    Online Resource
    Ovid Technologies (Wolters Kluwer Health) ; 2015
    In:  The Journal of Bone and Joint Surgery-American Volume Vol. 97, No. 14 ( 2015-07), p. 1142-1148
    In: The Journal of Bone and Joint Surgery-American Volume, Ovid Technologies (Wolters Kluwer Health), Vol. 97, No. 14 ( 2015-07), p. 1142-1148
    Type of Medium: Online Resource
    ISSN: 0021-9355
    RVK:
    Language: English
    Publisher: Ovid Technologies (Wolters Kluwer Health)
    Publication Date: 2015
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
  • 4
    Online Resource
    Online Resource
    Ovid Technologies (Wolters Kluwer Health) ; 2010
    In:  The Journal of Bone and Joint Surgery-American Volume Vol. 92, No. 8 ( 2010-07), p. 1715-1719
    In: The Journal of Bone and Joint Surgery-American Volume, Ovid Technologies (Wolters Kluwer Health), Vol. 92, No. 8 ( 2010-07), p. 1715-1719
    Type of Medium: Online Resource
    ISSN: 0021-9355
    RVK:
    Language: English
    Publisher: Ovid Technologies (Wolters Kluwer Health)
    Publication Date: 2010
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
  • 5
    Online Resource
    Online Resource
    Ovid Technologies (Wolters Kluwer Health) ; 2011
    In:  Clinical Orthopaedics & Related Research Vol. 469, No. 12 ( 2011-12), p. 3423-3428
    In: Clinical Orthopaedics & Related Research, Ovid Technologies (Wolters Kluwer Health), Vol. 469, No. 12 ( 2011-12), p. 3423-3428
    Type of Medium: Online Resource
    ISSN: 0009-921X
    RVK:
    Language: English
    Publisher: Ovid Technologies (Wolters Kluwer Health)
    Publication Date: 2011
    detail.hit.zdb_id: 2018318-5
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
  • 6
    Online Resource
    Online Resource
    Ovid Technologies (Wolters Kluwer Health) ; 2012
    In:  Clinical Orthopaedics & Related Research Vol. 470, No. 12 ( 2012-12), p. 3515-3523
    In: Clinical Orthopaedics & Related Research, Ovid Technologies (Wolters Kluwer Health), Vol. 470, No. 12 ( 2012-12), p. 3515-3523
    Type of Medium: Online Resource
    ISSN: 0009-921X
    RVK:
    Language: English
    Publisher: Ovid Technologies (Wolters Kluwer Health)
    Publication Date: 2012
    detail.hit.zdb_id: 2018318-5
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
  • 7
    Online Resource
    Online Resource
    Ovid Technologies (Wolters Kluwer Health) ; 2022
    In:  Journal of Bone and Joint Surgery Vol. 104, No. Suppl 2 ( 2022-4-6), p. 68-75
    In: Journal of Bone and Joint Surgery, Ovid Technologies (Wolters Kluwer Health), Vol. 104, No. Suppl 2 ( 2022-4-6), p. 68-75
    Abstract: Long-term follow-up results of ceramic-on-ceramic (COC) total hip arthroplasty (THA), specifically, in patients with osteonecrosis of the femoral head (ONFH) are unknown. We evaluated (1) clinical results and radiological outcomes, (2) ceramic-related complications: noise and ceramic fracture, (3) osteolysis, and (4) survivorship after alumina COC THA in ONFH patients with longer than 10-year follow-up. Methods: From May 2003 to June 2009, 325 ONFH patients (403 hips) underwent primary THAs at our department. Among them, 231 patients (293 THAs) were followed for 10 to 16 (mean, 12.9) years. There were 148 men and 83 women, their mean age at the time of THA was 47.2 years, and their mean body index was 24.0 kg/m 2 . The postoperative CT scans were done in 160 hips. Results: Grinding sensation or squeak was noted in 6.8% (20/293), ceramic head fracture occurred in 2.4% (7/293) and acetabular osteolysis developed in 0.7% (2/293). All 7 ceramic fractures occurred in 28-mm short-neck heads. There was no detectable wear or prosthetic loosening, and the 16-year survivorship was 96.0% (95% confidence interval; 93.8% to 98.2%). The mean Harris hip score was 91.7 (range, 84 to 100) points at the final follow-up. Conclusions: The 10- to 16-year results of alumina COC THAs were encouraging with an excellent survivorship. However, ceramic fracture and noise still remain matters of concern. We recommend not to use 28-mm short-neck ceramic head to avoid ceramic head fractures. Level of Evidence: III
    Type of Medium: Online Resource
    ISSN: 0021-9355 , 1535-1386
    RVK:
    Language: English
    Publisher: Ovid Technologies (Wolters Kluwer Health)
    Publication Date: 2022
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
  • 8
    Online Resource
    Online Resource
    Ovid Technologies (Wolters Kluwer Health) ; 2022
    In:  Clinical Orthopaedics & Related Research Vol. 480, No. 4 ( 2022-04), p. 690-699
    In: Clinical Orthopaedics & Related Research, Ovid Technologies (Wolters Kluwer Health), Vol. 480, No. 4 ( 2022-04), p. 690-699
    Abstract: Recently, impingement between the femoral stem and ceramic liner, which appears as a notch in the stem neck on radiographs, has emerged as a new complication. However, the proportion of impingement, potential risk factors, and related complications are poorly elucidated. Question/purposes In patients who underwent ceramic-on-ceramic (CoC) THA and had at least 10 years of follow-up, we asked: (1) What proportion had radiographic evidence of stem neck–ceramic liner impingement (notching of the stem), and what implant design, implantation factors, or complications such as ceramic fracture or metallosis are associated with impingement? (2) How common are the complications of noise and ceramic fracture? (3) What are the radiologic changes (including fixation of femoral and acetabular components, osteolysis, and heterotopic ossification) and clinical outcomes as determined by the modified Harris hip score (mHHS) for this cohort? (4) What is the survivorship with implant revision as the endpoint and with reoperation for any reason as the endpoint after CoC THA using a thick-neck stem design? Methods Between May 2003 and April 2010, 643 patients underwent primary THA at a tertiary referral hospital. After excluding patients with metal-on-polyethylene and with ceramic-on-polyethylene implants, 621 patients were considered eligible for this study. All patients received the same hemispherical titanium cup, a standard-length tapered titanium stem, and a CoC bearing. Of those, 19% (115) were lost to follow-up before 10 years, and 8% (50) were excluded because they died before the minimum follow-up duration of 10 years, leaving 73% (456) for analysis. Patients had a mean age of 50 ± 14 years and were followed for a median (range) of 13 years (10 to 17). The mean cup abduction was 38° ± 5°, and the mean cup anteversion was 26° ± 7°. To determine the proportion of patients with the neck-liner impingement, we analyzed the plain radiographs of every patient during follow-up to detect notches around the stem. The detection of stem neck notches on the radiographs was reliable (intraobserver reliability: κ = 0.963; p 〈 0.001 and interobserver reliability: κ = 0.975; p 〈 0.001). To evaluate factors related to notching, we compared the possible confounding factors including gender, age, BMI, implant position, neck length, and head diameter. Complications such as ceramic fracture, noise, dislocation, and periprosthetic joint infection were recorded. Noise was evaluated via interview and with the Hip Noise Assessment Questionnaire, which assessed the noise qualitatively. For clinical outcome, we assessed the mHHS, which includes pain and function scales (0 [worst] to 100 [best] ), every visit. Tilting of at least 4° or migration of at least 4 mm was the criteria for cup loosening; subsidence more than 3 mm, any change in position, or a continuous radiolucent line greater than 2 mm was the criteria for stem loosening. To evaluate osteolysis, we performed CT scans in 57% (262 of 456) of patients. Kaplan-Meier survivorship analysis was performed using the endpoints of survivorship free from implant revision and survivorship free from reoperation for any cause. Results The proportion of stem neck notching was 11% (49 of 456). There were no differences in cup abduction and anteversion between hips with notches and those without notches. Notched hips were more likely to have 28-mm than 32-mm heads (90% [44 of 49] versus 70% [285 of 407] ; odds ratio 3.77 [95% CI 1.46 to 9.73]; p = 0.004). None of the 49 notched hips had a ceramic head or liner fracture or evidence of metallosis. A ceramic head fracture was reported in 2% (9 of 456); all fractures occurred in 28-mm short neck heads. A ceramic liner fracture occurred in 0.2% (1 of 456), and noise was noted in 6% (27 of 456). Acetabular osteolysis developed in 2% (7 of 456). The mHHS was 91 ± 12 points at the final follow-up. The survivorship free from implant revision was 97% (95% CI 96% to 99%), and the survivorship free from reoperation for any cause was 96% (95% CI 95% to 98%) at 13 years. Conclusion The proportion of stems with neck–ceramic liner impingement and ceramic component fracture were unacceptably high after the use of a thick-neck stem design, especially when a 28-mm head was used. We have discontinued the use of this stem design and we recommend that such stems should not be used when CoC bearings are used. As these findings might be generalized to other bearing couples, further studies focused on polyethylene liner wear and local metallosis due to thick stem neck are warranted. Level of Evidence Level III, therapeutic study.
    Type of Medium: Online Resource
    ISSN: 0009-921X , 1528-1132
    RVK:
    Language: English
    Publisher: Ovid Technologies (Wolters Kluwer Health)
    Publication Date: 2022
    detail.hit.zdb_id: 2018318-5
    Location Call Number Limitation Availability
    BibTip Others were also interested in ...
Close ⊗
This website uses cookies and the analysis tool Matomo. More information can be found here...